Nova-tech pH 110 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Equipamento Nova-tech pH 110. Nova-Tech pH 110 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 76
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Instruction Manual
pH 11 & pH 110
Hand-held pH / mV / Temperature / RS 232 Meter
Tech n ol o
g
y
M
ade
E
a
s
y
.
.
.
68X361301
Rev. 2 - 11/03
Vista de página 0
1 2 3 4 5 6 ... 75 76

Resumo do Conteúdo

Página 1 - Instruction Manual

Instruction Manual pH 11 & pH 110 Hand-held pH / mV / Temperature / RS 232 Meter Tech n ol ogyMadeEasy...68X361301 Rev. 2 - 11/03

Página 2 - Rev. 2 - 11/03

Instruction Manual CyberScan pH 11 / 110 6 3.2 Connecting the pH Electrode Temperature Probe & Electrode HolderThe pH 11/110 meter uses any

Página 3 - TABLE OF CONTENTS

Instruction Manual CyberScan pH 11 / 110 73.2.2 To connect the temperature probe: The temperature probe (provided) uses a 2.5 mm phono jack to

Página 4

Instruction Manual CyberScan pH 11 / 110 81. Align the flange of the second electrode holder with the slot of the first holder (Figure 8). 2.

Página 5 - 1 INTRODUCTION

Instruction Manual CyberScan pH 11 / 110 93.3 Connecting the AC/DC AdapterBesides using four AAA-sized batteries as a power source, the pH 11/1

Página 6 - 1. SETUP - Setup mode

Instruction Manual CyberScan pH 11 / 110 103.4.1 RS232C ConfigurationThe pH 110 meter has a 9 pin female RS232C connector with the following pin

Página 7 - 2.2 Keypad

Instruction Manual CyberScan pH 11 / 110 114 CALIBRATION 4.1 Important Information on Meter Calibration When you re-calibrate your meter, prev

Página 8

Instruction Manual CyberScan pH 11 / 110 12 4.2.1 pH 11 meter calibration The pH 11 meter is capable of up to 5-point pH calibration to ensure

Página 9 - MADE IN S'PORE

Instruction Manual CyberScan pH 11 / 110 134.3 pH Calibration with ATCNOTE: We recommend that you perform at least 2-point calibration using st

Página 10

Instruction Manual CyberScan pH 11 / 110 14 7. Rinse the probe with de-ionised water or a rinse solution, and place it in the next pH buffer.

Página 11

Instruction Manual CyberScan pH 11 / 110 154.4 mV Calibration (Offset) (Only for pH 110)With pH 110 meter, you can perform a calibration or an

Página 12

PrefaceThis manual serves to explain the use of the hand-held series meters. The models covered are the pH 11 and the pH 110 hand-held meters. The ma

Página 13 - Figure 10: Location of

Instruction Manual CyberScan pH 11 / 110 164.5 Temperature CalibrationThe temperature sensor is factory calibrated. Calibrate the temperature pr

Página 14

Instruction Manual CyberScan pH 11 / 110 175 MEASUREMENT This meter is capable of taking measurements with automatic or manual temperature compe

Página 15 - 4 CALIBRATION

Instruction Manual CyberScan pH 11 / 110 185.2 Manual Temperature CompensationIMPORTANT: For manual compensation, you must disconnect the tempe

Página 16

Instruction Manual CyberScan pH 11 / 110 195.3 Taking MeasurementsBe sure to remove the electrode soaker bottle or protective rubber cap on the

Página 17 - 4.3 pH Calibration with ATC

Instruction Manual CyberScan pH 11 / 110 206 HOLD FUNCTION This feature lets you freeze the value of the pH, mV (or relative mV) and temperature

Página 18 - Figure 12: Proceed to next

Instruction Manual CyberScan pH 11 / 110 217 MEMORY FUNCTION The memory function is available in both pH 11 and pH 110 meters. These meters stor

Página 19 - Offset on page 40

Instruction Manual CyberScan pH 11 / 110 227.2 Memory Recall This function recalls the previous readings stored in the memory. You can only acce

Página 20 - 4.5 Temperature Calibration

Instruction Manual CyberScan pH 11 / 110 238 PRINT FUNCTION (Only for pH 110) The pH 110 meter is equipped with an RS232 communication port and

Página 21 - 5 MEASUREMENT

Instruction Manual CyberScan pH 11 / 110 24Running CyberComm Portable on page 52. 6. To send data to the printer or computer, press the PRINT

Página 22

Instruction Manual CyberScan pH 11 / 110 258.2.1 Print Current Data Manually To manually print any data that is currently being measured: 1.

Página 23 - 5.3 Taking Measurements

TABLE OF CONTENTS 1 INTRODUCTION...

Página 24 - 6 HOLD FUNCTION

Instruction Manual CyberScan pH 11 / 110 265 10secsecFrom measurement mode"MEM" annunicator will keep flashing during measurement mode

Página 25 - 7 MEMORY FUNCTION

Instruction Manual CyberScan pH 11 / 110 274. Press HOLD/ENTER key. The “Prn” primary display will flash until all data is printed. 5. To sto

Página 26 - 7.2 Memory Recall

Instruction Manual CyberScan pH 11 / 110 28pHMEASREADY 23.47.03During measurement modeRepeat print procedure or press CAL to exit°CFor example,s

Página 27

Instruction Manual CyberScan pH 11 / 110 299 ADVANCED SETUP FUNCTIONS The advanced setup mode lets you customised your meter’s preferences and d

Página 28

Instruction Manual CyberScan pH 11 / 110 30From pH measurement mode From mV measurement modeSETUP SETUPMEM P 1.0 P 1.0SETUPpHCAL P 2.0SETUPELE

Página 29 - Flash for 0.5 seconds

Instruction Manual CyberScan pH 11 / 110 319.1 Advanced SETUP Mode OverviewPress the SETUP key to enter Setup mode. Press the MI/ and MR/ key

Página 30 - From measurement mode

Instruction Manual CyberScan pH 11 / 110 32 9.1.2 mV Setup mode SETUP P 1.0COF P1.0: Unit Configuration P1.1 Ready indicator (On, Off or Auto

Página 31 - To stop, press PRINT key

Instruction Manual CyberScan pH 11 / 110 339.2 P1.0 : Unit Configuration This subgroup program allows customising the meter to your specific ne

Página 32 - Repeat print procedure or

Instruction Manual CyberScan pH 11 / 110 34 9.2.1 P1.1: READY Indicator and Auto Hold function Program P1.1 lets you select “READY indicator on

Página 33 - 9 ADVANCED SETUP FUNCTIONS

Instruction Manual CyberScan pH 11 / 110 359.2.2 P1.2: Select Calibration Buffer Options The types of pH calibration buffer options available a

Página 34 - only in PH 110 but

9.3 P2.0: VIEWING PREVIOUS CALIBRATION DATA ... 389.4 P3.0: VIEW ELE

Página 35 - P3.2 pH electrode slope

Instruction Manual CyberScan pH 11 / 110 369.2.3 P1.3 Select Number of pH Calibration Points Program P1.3 lets you select the number of calibra

Página 36

Instruction Manual CyberScan pH 11 / 110 379.2.4 P1.4 Select °C or °F Temperature Units Available in pH 110 meter only The pH 110 meter lets yo

Página 37

Instruction Manual CyberScan pH 11 / 110 38 9.3 P2.0: Viewing Previous Calibration Data This mode lets you recall previous calibration data, wh

Página 38

Instruction Manual CyberScan pH 11 / 110 399.4 P3.0: View Electrode DataProgram 3 has two “view only” options that let you check the electrode

Página 39

Instruction Manual CyberScan pH 11 / 110 409.4.2 View mV Offset (Only for pH 110) If you are in mV measurement mode, the display shows the rela

Página 40 - Figure 32: P1.3 - Select

Instruction Manual CyberScan pH 11 / 110 419.5 P4.0 : Auto-OffIn Program P4.0 you can activate the AUTO-OFF option to automatically power off t

Página 41 - Figure 33: P1.4 - Select

Instruction Manual CyberScan pH 11 / 110 429.6 P5.0 : Reset to Factory DefaultThis mode lets you reset all parameters to factory default settin

Página 42 - Figure 34: P2.0 - View

Instruction Manual CyberScan pH 11 / 110 43 NOTE:Calibration reset is independent for each measurement parameter. That is:x From pH mode, calib

Página 43 - From pH measurement mode:

Instruction Manual CyberScan pH 11 / 110 449.7 P 6.0: Memory Clear (CLr)Use this parameter to clear all memory values when you need to store a

Página 44 - Figure 36: P3.0 - View mV

Instruction Manual CyberScan pH 11 / 110 4510 CYBERCOMM PORTABLE DAS (Only for pH 110) The DAS software is designed for pH 110, CON 110 and DO

Página 45 - 9.5 P4.0 : Auto-Off

Instruction Manual CyberScan pH 11 / 110 11 INTRODUCTION Thank you for selecting the pH 11/110 meter. These meters are microprocessor-based inst

Página 46

Instruction Manual CyberScan pH 11 / 110 46 Figure 42: Click on 'Browse' button and locate CD-ROM drive Figure 43: Locate the Cyber

Página 47 - Figure 39: P5.2 - User reset

Instruction Manual CyberScan pH 11 / 110 47 Figure 44: Select ‘Portable Meters’ directory to go to CyberComm Portable. Figure 45: Open ‘CyberC

Página 48 - SETUP MEM

Instruction Manual CyberScan pH 11 / 110 48 Figure 46: Select "SETUP.EXE" program and click the OPEN button Figure 47: InstallShiel

Página 49 - 10.1 System Requirements

Instruction Manual CyberScan pH 11 / 110 49 Figure 48: Click on Next button Figure 49: Key in your name and company name and click NEXT butto

Página 50

Instruction Manual CyberScan pH 11 / 110 50 Figure 50: To select another Destination Directory to install the program, click on BROWSE button.

Página 51

Instruction Manual CyberScan pH 11 / 110 51 Figure 52: Click on NEXT button. Figure 53: The CyberComm Portable DAS program is fully installed

Página 52

Instruction Manual CyberScan pH 11 / 110 5210.3 Running CyberComm PortableBefore running the DAS program, please ensure that the RS232 cable is

Página 53

Instruction Manual CyberScan pH 11 / 110 5310.3.1 Buttons & Check-Box x Enable Connection - Click this button to enable communication betwe

Página 54

Instruction Manual CyberScan pH 11 / 110 54x Exit - To exit from CyberComm Data Acquisition Software program. Figure 57: Communication Settin

Página 55

Instruction Manual CyberScan pH 11 / 110 55 10.4 Capturing And Printing Data Into Computer Using Data Acquisition After matching the Communicat

Página 56

Instruction Manual CyberScan pH 11 / 110 22 DISPLAY & KEYPAD FUNCTIONS 2.1 DisplayThe LCD has a primary and secondary display. x The prima

Página 57

Instruction Manual CyberScan pH 11 / 110 56 10.5 Trouble-shooting Guidea) Problem: Unable to PRINT When press PRINT key on pH 110 meter, nothin

Página 58

Instruction Manual CyberScan pH 11 / 110 5711 ELECTRODE CARE 11.1 Electrode MaintenancepH electrodes are susceptible to dirt and contamination a

Página 59

Instruction Manual CyberScan pH 11 / 110 58rejuvenate it. (See section 11.4 on Rejuvenation Procedure). 11.2 Electrode CleaningElectrodes that a

Página 60 - 10.5 Trouble-shooting Guide

Instruction Manual CyberScan pH 11 / 110 5911.4 Rejuvenation Procedure1. Dip and stir the electrode in freon or alcohol for 5 minutes. 2. Leav

Página 61 - 11 ELECTRODE CARE

Instruction Manual CyberScan pH 11 / 110 6012 ERROR MESSAGES The following table provides a guideline to enable diagnosis of possible problems i

Página 62 - 11.3 Electrode Activation

Instruction Manual CyberScan pH 11 / 110 6113 TROUBLE-SHOOTING PROBLEM PROBABLE CAUSE REMEDIAL ACTIONNothing is displayed when the ON/OFF key i

Página 63 - 11.4 Rejuvenation Procedure

Instruction Manual CyberScan pH 11 / 110 6214 INFORMATION ON pH MEASUREMENT & ELECTRODEThe previous sections of this manual describe the va

Página 64 - 12 ERROR MESSAGES

Instruction Manual CyberScan pH 11 / 110 6314.1.3 pH and Temperature The electromotive force generated in the glass electrode varies with the t

Página 65 - 13 TROUBLE-SHOOTING

Instruction Manual CyberScan pH 11 / 110 6414.3 Standard pH BuffersThe following table shows the various pH values at different temperature of

Página 66 - 14.1 pH Measurements

Instruction Manual CyberScan pH 11 / 110 6515 LIST OF ACCESSORIES 15.1 Replacement Meter and Meter accessoriesEutech Instruments ItemEutech In

Página 67

Instruction Manual CyberScan pH 11 / 110 3 2.2 Keypad A large membrane keypad makes the instrument easy to use. Each button, when pressed, has

Página 68 - 14.3 Standard pH Buffers

Instruction Manual CyberScan pH 11 / 110 6615.2 Oakton InstrumentsItemOakton Instruments Order Code CyberScan pH 11 Portable pH/mV Meter with 2

Página 69 - Eutech Instruments

Instruction Manual CyberScan pH 11 / 110 6715.3 Calibration SolutionsItemEutechInstruments Order CodeOaktonInstruments Order CodepH 4.01 buffer

Página 70 - 15.2 Oakton Instruments

Instruction Manual CyberScan pH 11 / 110 6816 FACTORY DEFAULT SETTINGS 16.1 pH 11 Factory Default SettingsPROGRAM FUNCTION PARAMETER OPTING

Página 71 - 15.3 Calibration Solutions

Instruction Manual CyberScan pH 11 / 110 6916.2 pH 110 Factory Default SettingsPROGRAM FUNCTION PARAMETER OPTING KEYS PARAMETEROPTIONSDEFAULTS

Página 72

Instruction Manual CyberScan pH 11 / 110 7017 SPECIFICATIONS MODEL NO. pH 11 pH 110 pH Range -2.00 to 16.00 pH -2.00 to 16.00 pH Resolutio

Página 73

Instruction Manual CyberScan pH 11 / 110 7118 WARRANTY This meter is supplied with a three-year warranty, six-month warranty for probe against s

Página 75 - 19 RETURN OF ITEMS

Instruction Manual CyberScan pH 11 / 110 4 MODEMEASCALENTERHOLDMRMISETUPOFFONMI MRSETUP MODEMEASCALENTERHOLDOFFONKeypad for pH 11 meter Keypa

Página 76

Instruction Manual CyberScan pH 11 / 110 53 PREPARATION 3.1 Inserting the BatteriesThis meter is packaged with 4 “AAA” alkaline batteries requir

Modelos relacionados pH 11

Comentários a estes Manuais

Sem comentários